PDA2700 Series Steel NEMA 4 Enclosures

SKU: PDA2700 Categoría:

Descripción

Features

  • House up to 6 Meters
  • 16-Gauge Type 304 Steel
  • 14-Gauge Type 304 Steel
  • 1/8 DIN Cutout(s) Pre-Cut
  • Horizontal, Vertical, or No Cutouts
  • NEMA 4, 12 and 13
  • Cover Secured with Screwed Latches
  • Hinged Door
  • Meter Mounted in Cover
  • Sub-Panels Available
  • Mounting Holes Integral to Enclosure
  • PDA1024-01 24 VDC Power Supply Available
  • UL Listed, CSA Certified
  • Light / Horn / Reset Switch Option

Overview

The PDA2700 series of steel NEMA 4X enclosures for 1/8 DIN Digital Panel Meters provide a convenient way to mount up to six Precision Digital meters to walls and other vertical structures. Many of these enclosures also have room for additional devices like a red light / horn and a 24 VDC transmitter power supply. These enclosures come pre- cut with horizontal or vertical 1/8 DIN cutouts or they can be ordered with no cutouts. The meters are mounted in the door of the enclosure thus allowing for programming and operation of the meter. No additional mounting hardware other than screws is needed. The door is hinged and secured with latches. Enclosures, meters and accessories are ordered and packaged separately.

Wall Mounting

The PDA2700 enclosures include integral mounting flanges attached at the top and bottom of the enclosure that can be used to mount the enclosures to a wall.

Wall mountingMounting flange for wall mounting

Cover Securing Method

The cover is secured in place with screwed latches.

Cover Securing Method

Accessories

Sub-Panels

Sub-PanelsThe PDP2503 & PDP2504 sub-panels provide a convenient way to mount additional items to the base of the enclosure. They can be drilled to accept screws for easy mounting of relays, contactors, securing wiring clips, or installing other internal devices. See chart below for compatibility.

Sub-Panel Specifications

Size:
PDP2503: 8.75″ × 6.88″
(222 mm × 175 mm)
PDP2504: 10.75″ × 10.88″
(273 mm × 276 mm)
Thickness: 14 gauge
Material: Steel
Mounting hardware is included.

Model PDP2503 PDP2504
Horizontal Cutouts
PDA2701
PDA2702
PDA2703
PDA2703-1
PDA2703-2
PDA2704
PDA2704-1
PDA2704-1C
PDA2704-2
PDA2704-2C
PDA2704-3
PDA2704-3C
PDA2705
PDA2706
PDA2713
Vertical Cutouts
PDA2701-V
PDA2702-V
PDA2703-V
PDA2704-V
PDA2705-V
PDA2706-V
PDA2722
No Cutouts
PDA2703-B
PDA2706-B

PDA1024-01 24 VDC Power Supply for DIN Rail

PDA1024-01 24 VDC Power Supply for DIN RailThe PDA1024-01 is a DIN rail mounted 24 VDC, 1.5 A power supply.

Specifications

Output Voltage: 21.6 ~ 26.4 VDC; ±10% 1.5A rated current.
Dimensions: 3.07″ x 3.66″ x 2.20″
(78 mm x 93 mm x 56 mm) (W x H x D)

PDA-SSTAG Stainless Steel Tags

PDA-SSTAG Stainless Steel TagsPDA-SSTAG is a laser etched stainless steel tag accessory for any of your Precision Digital meters. The tag features custom text for equipment identification, instruction, or whatever else is needed in your facility. Each tag comes with a stainless steel wire and lead seal for easy mounting wherever you need it.

PDX18DIN-FILLER 1/8 DIN Cutout Filler

PDX18DIN-FILLER 1/8 DIN Cutout FillerThe NEMA 4X 1/8 DIN cutout filler is used to cover up empty 1/8 DIN cutouts and maintain the NEMA 4X rating to the panel or enclosure. It consists of a generic bezel with a black faceplate, as well as mounting brackets, gasket, etc.

PDA2700 Series Enclosure with Light / Horn

PDA2700 Series Enclosure with Light / Horn

Light / Horn Accessories

Precision Digital offers a Light / Horn that can be mounted to any PDA2700 Series enclosures by the user. This Light / Horn can be wired to flash or stay steady on and the horn is rated at 85 dB. The light and horn can be controlled independently of each other via separate relays on the meter such that the horn can be programmed to silence via a button mounted to the enclosure and the light can be programmed to stay on until the alarm clears.

The light / horn and reset button are all rated NEMA 4X or IP65. The following table illustrates a typical way the Light / Horn option can be wired and programmed for the ProVu meter:

Relay # Connected to Typical reset method
(user selectable)
1 Flashing Light(1) Reset automatically after alarm clears
2 Horn Silence with Reset Button at any time
3 User Device As user desires
4 User Device As user desires

1. Light can be wired to flash or stay steady on

Note: The Light / Horn option is powered from the 200 mA transmitter power supply, so when that option is installed, the meter’s transmitter power is downgraded from 200 mA. See isolated Transmitter Power Supply specification on meter’s data sheet for details.

PDA1024-01 Mounted on PDP2504 Sub-Panel

MOD-LRHB1

When this MOD is ordered, the enclosure comes pre-drilled with holes for Light / Horn and Reset Button to be installed by user. The Light / Horn hole is in the back left corner of the enclosure and the Reset button is centered on the front of the enclosure about an inch off the bottom of the door. If the user would prefer to mount these items in different locations, order the PDA-LRH and the PDA-BUTTON1R separately and drill holes and mount as desired.

Light / Horn Dimensions Units: Inches (mm)

Light / Horn Dimensions

wpChatIcon
wpChatIcon