H241 Helical Flow Meter

Flow 100 cc/min to 189 liters/min; 0 to 50 gpm
Port Size 1.5″ NPT or 1.5″ (DN40) flange
Accuracy (at 30cp): ± 0.2% of reading over 50:1 range
Pressure 500 or 3500 psi (35 or 240 bar)
K-Factor 15,000 pulses/L
Fluids Most non aqueous, hydrocarbon based liquids

Descripción

Mechanical
Filtration
150 Micron recommended
Weight
13.6 kg (30.0 lbs)
Materials of Construction
External
Stainless Steel, type 303
Wetted
Stainless Steel, type 303, 440C
O-Rings
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer
Transmitter Variations
Signal Type
Output
Resolution (K-Factor)
Std. Temp†
High Temp†
Ultra Temp
Frequency
5 VDC square wave (current sinking available)
15,000 pulses/L
90°C
EX†
225°C
Frequency
5 VDC quadrature (2-phase)
7500 pulses/L/phase
90°C
EX†
225°C
Analog
0-10 VDC
Uni or Bi-directional
90°C
EX†
225°C
Analog
4-20 mA
Uni or Bi-directional
90°C
EX†
225°C
Compliance:
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx. †Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.

 

 