Descripción
Mechanical
Filtration
|
15 Micron recommended
|
Weight
|
1.8 kg (3.96 lbs)
|
Materials of Construction
External
|
Stainless steel, type 303 – See G015HZ for type 316
|
Wetted
|
Stainless steel, type 303, 440C, 17-4
|
O-Rings
|
Standard: Viton®
Optional: Teflon®, Perfluoroelastomer |
Transmitter Variations
Signal Type
|
Output
|
Resolution (K-Factor)
|
Std. Temp†
|
High Temp†
|
Ultra Temp
|
---|---|---|---|---|---|
Frequency
|
5 VDC square wave (current sinking available)
|
200 pulses/cc
|
90°C
|
155°C
|
225°C
|
Frequency
|
5 VDC quadrature (2-phase)
|
100 pulses/cc/phase
|
90°C
|
155°C
|
225°C
|
Analog
|
0-10 VDC
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Analog
|
4-20 mA
|
Uni or Bi-directional
|
90°C
|
155°C
|
225°C
|
Compliance:
|
CE Certified, Ex-proof version available with ATEX/IECEx II 2 G Ex db IIB Tx Gb as well as UL, cUL certification for Class 1, Division 1, Groups C and D, Tx. †Maximum temperature rating for ATEX certified transmitters is 75°C Std. Temp and 130°C High Temp.
|
-